Test Station
Services
for testing devices, equipment, assemblies, etc.
1. Environmental
Tests (durability, immunity):
-
cold chamber - (-20º ± 3º)С payload volume up to 20m3;
-
(-50º ± 3°)С, payload
volume up to 50m3;
-
cold chamber - (0º ± 3º)С to (-50º ± 3°)С, payload volume 12000dm3;
-
hot chamber - (50º ± 3º)С, payload volume up to 100m3;
-
humidity chamber – relative
humidity 65 ±15%, 95 ±3% at temperatures of - 10ºС, 20ºС, 35ºС, 40ºС;
-
low pressure chamber – from 2 х 10-1at, with the volume of 2000dm3;
-
dust chamber – air circulation rate (0.5 – 1.0)m/sec., at a temperature of 50ºС;
-
temperature box – from
100ºС to 250ºС;
-
rain chamber.
2.
Mechanical Tests (vibration strength, vibration resistance):
Description
|
Frequencies range
|
Maximum acceleration
m/sec2 (g)
|
Maximum static load, kg
|
Pulse length, ms
|
Maximum gain,
Н
|
Vibration bed
ВЭДС-1500
|
(20 – 1500) Hz
|
430 (43)
|
300
|
|
15000
|
Shock table
STT- 500
|
17 – 180min-1
|
80 - 500
|
400
|
0.5 - 10
|
|
Shock table
TIRASHOCK-
- 4110
|
up to 3Hz
|
10000
|
450
|
up to 30
|
|
Transportation imitation bench
МТ200М
|
40 –80 min-1
|
19,6 - 98,0
(2-10)
|
200
|
|
|
Shock table СУ –1
|
10 – 100min-1
|
(10 – 150)
|
50
|
1±0.5 up to 15±2
|
|
|